Update LCD timing on Formbot T-Rex 2+ machines
The code is slightly more optimized than it used to be and this has caused the setup and hold times on the Formbot T-Rex 2+ machines to be insufficient. This change gives sufficient margin and the LCD Display is clean again.
This commit is contained in:
parent
5d515c3a2f
commit
075a86b076
@ -21,6 +21,15 @@
|
||||
*/
|
||||
#pragma once
|
||||
|
||||
/**
|
||||
* Override default LCD timing for Formbot T-Rex 2+ machines.
|
||||
* The long LCD cables and the routing near electrically noisy stepper motors
|
||||
* requires a slightly longer setup and hold time on the signals.
|
||||
*/
|
||||
#define BOARD_ST7920_DELAY_1 DELAY_NS(200)
|
||||
#define BOARD_ST7920_DELAY_2 DELAY_NS(200)
|
||||
#define BOARD_ST7920_DELAY_3 DELAY_NS(200)
|
||||
|
||||
/**
|
||||
* Formbot pin assignments
|
||||
*/
|
||||
|
Loading…
Reference in New Issue
Block a user