add RepRapPro Huxley thermistor tables

This commit is contained in:
Daniele Sdei 2012-12-30 12:09:38 +01:00
parent 5f82f03ff3
commit 3cf59f6f9a
2 changed files with 101 additions and 1 deletions

View File

@ -68,6 +68,9 @@
// 5 is 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan) (4.7k pullup) // 5 is 100K thermistor - ATC Semitec 104GT-2 (Used in ParCan) (4.7k pullup)
// 6 is 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup) // 6 is 100k EPCOS - Not as accurate as table 1 (created using a fluke thermocouple) (4.7k pullup)
// 7 is 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup) // 7 is 100k Honeywell thermistor 135-104LAG-J01 (4.7k pullup)
// 8 is 100k 0603 SMD Vishay NTCS0603E3104FXT (4.7k pullup)
// 9 is 100k GE Sensing AL03006-58.2K-97-G1 (4.7k pullup)
// 10 is 100k RS thermistor 198-961 (4.7k pullup)
// //
// 1k ohm pullup tables - This is not normal, you would have to have changed out your 4.7k for 1k // 1k ohm pullup tables - This is not normal, you would have to have changed out your 4.7k for 1k
// (but gives greater accuracy and more stable PID) // (but gives greater accuracy and more stable PID)

View File

@ -312,6 +312,103 @@ const short temptable_7[][2] PROGMEM = {
{1023*OVERSAMPLENR, 0} //to allow internal 0°C {1023*OVERSAMPLENR, 0} //to allow internal 0°C
}; };
#endif #endif
#if (THERMISTORHEATER_0 == 8) || (THERMISTORHEATER_1 == 8) || (THERMISTORHEATER_2 == 8) || (THERMISTORBED == 8)
// 100k 0603 SMD Vishay NTCS0603E3104FXT (4.7k pullup)
const short temptable_8[][2] PROGMEM = {
{1*OVERSAMPLENR, 704},
{54*OVERSAMPLENR, 216},
{107*OVERSAMPLENR, 175},
{160*OVERSAMPLENR, 152},
{213*OVERSAMPLENR, 137},
{266*OVERSAMPLENR, 125},
{319*OVERSAMPLENR, 115},
{372*OVERSAMPLENR, 106},
{425*OVERSAMPLENR, 99},
{478*OVERSAMPLENR, 91},
{531*OVERSAMPLENR, 85},
{584*OVERSAMPLENR, 78},
{637*OVERSAMPLENR, 71},
{690*OVERSAMPLENR, 65},
{743*OVERSAMPLENR, 58},
{796*OVERSAMPLENR, 50},
{849*OVERSAMPLENR, 42},
{902*OVERSAMPLENR, 31},
{955*OVERSAMPLENR, 17},
{1008*OVERSAMPLENR, 0}
};
#endif
#if (THERMISTORHEATER_0 == 9) || (THERMISTORHEATER_1 == 9) || (THERMISTORHEATER_2 == 9) || (THERMISTORBED == 9)
// 100k GE Sensing AL03006-58.2K-97-G1 (4.7k pullup)
const short temptable_9[][2] PROGMEM = {
{1*OVERSAMPLENR, 936},
{36*OVERSAMPLENR, 300},
{71*OVERSAMPLENR, 246},
{106*OVERSAMPLENR, 218},
{141*OVERSAMPLENR, 199},
{176*OVERSAMPLENR, 185},
{211*OVERSAMPLENR, 173},
{246*OVERSAMPLENR, 163},
{281*OVERSAMPLENR, 155},
{316*OVERSAMPLENR, 147},
{351*OVERSAMPLENR, 140},
{386*OVERSAMPLENR, 134},
{421*OVERSAMPLENR, 128},
{456*OVERSAMPLENR, 122},
{491*OVERSAMPLENR, 117},
{526*OVERSAMPLENR, 112},
{561*OVERSAMPLENR, 107},
{596*OVERSAMPLENR, 102},
{631*OVERSAMPLENR, 97},
{666*OVERSAMPLENR, 92},
{701*OVERSAMPLENR, 87},
{736*OVERSAMPLENR, 81},
{771*OVERSAMPLENR, 76},
{806*OVERSAMPLENR, 70},
{841*OVERSAMPLENR, 63},
{876*OVERSAMPLENR, 56},
{911*OVERSAMPLENR, 48},
{946*OVERSAMPLENR, 38},
{981*OVERSAMPLENR, 23},
{1005*OVERSAMPLENR, 5},
{1016*OVERSAMPLENR, 0}
};
#endif
#if (THERMISTORHEATER_0 == 10) || (THERMISTORHEATER_1 == 10) || (THERMISTORHEATER_2 == 10) || (THERMISTORBED == 10)
// 100k RS thermistor 198-961 (4.7k pullup)
const short temptable_10[][2] PROGMEM = {
{1*OVERSAMPLENR, 929},
{36*OVERSAMPLENR, 299},
{71*OVERSAMPLENR, 246},
{106*OVERSAMPLENR, 217},
{141*OVERSAMPLENR, 198},
{176*OVERSAMPLENR, 184},
{211*OVERSAMPLENR, 173},
{246*OVERSAMPLENR, 163},
{281*OVERSAMPLENR, 154},
{316*OVERSAMPLENR, 147},
{351*OVERSAMPLENR, 140},
{386*OVERSAMPLENR, 134},
{421*OVERSAMPLENR, 128},
{456*OVERSAMPLENR, 122},
{491*OVERSAMPLENR, 117},
{526*OVERSAMPLENR, 112},
{561*OVERSAMPLENR, 107},
{596*OVERSAMPLENR, 102},
{631*OVERSAMPLENR, 97},
{666*OVERSAMPLENR, 91},
{701*OVERSAMPLENR, 86},
{736*OVERSAMPLENR, 81},
{771*OVERSAMPLENR, 76},
{806*OVERSAMPLENR, 70},
{841*OVERSAMPLENR, 63},
{876*OVERSAMPLENR, 56},
{911*OVERSAMPLENR, 48},
{946*OVERSAMPLENR, 38},
{981*OVERSAMPLENR, 23},
{1005*OVERSAMPLENR, 5},
{1016*OVERSAMPLENR, 0}
};
#endif
#if (THERMISTORHEATER_0 == 51) || (THERMISTORHEATER_1 == 51) || (THERMISTORHEATER_2 == 51) || (THERMISTORBED == 51) #if (THERMISTORHEATER_0 == 51) || (THERMISTORHEATER_1 == 51) || (THERMISTORHEATER_2 == 51) || (THERMISTORBED == 51)
// 100k EPCOS (WITH 1kohm RESISTOR FOR PULLUP, R9 ON SANGUINOLOLU! NOT FOR 4.7kohm PULLUP! THIS IS NOT NORMAL!) // 100k EPCOS (WITH 1kohm RESISTOR FOR PULLUP, R9 ON SANGUINOLOLU! NOT FOR 4.7kohm PULLUP! THIS IS NOT NORMAL!)