Fix G26 error return

This commit is contained in:
Scott Lahteine 2017-11-25 19:53:14 -06:00
parent 9badf5dc0d
commit 41ec449960

View File

@ -483,7 +483,7 @@ inline bool turn_on_heaters() {
/**
* Prime the nozzle if needed. Return true on error.
*/
bool prime_nozzle() {
inline bool prime_nozzle() {
#if ENABLED(NEWPANEL)
float Total_Prime = 0.0;
@ -582,7 +582,7 @@ void GcodeSuite::G26() {
g26_bed_temp = parser.value_celsius();
if (!WITHIN(g26_bed_temp, 15, 140)) {
SERIAL_PROTOCOLLNPGM("?Specified bed temperature not plausible.");
return G26_ERR;
return;
}
}
@ -590,7 +590,7 @@ void GcodeSuite::G26() {
g26_layer_height = parser.value_linear_units();
if (!WITHIN(g26_layer_height, 0.0, 2.0)) {
SERIAL_PROTOCOLLNPGM("?Specified layer height not plausible.");
return G26_ERR;
return;
}
}
@ -599,12 +599,12 @@ void GcodeSuite::G26() {
g26_retraction_multiplier = parser.value_float();
if (!WITHIN(g26_retraction_multiplier, 0.05, 15.0)) {
SERIAL_PROTOCOLLNPGM("?Specified Retraction Multiplier not plausible.");
return G26_ERR;
return;
}
}
else {
SERIAL_PROTOCOLLNPGM("?Retraction Multiplier must be specified.");
return G26_ERR;
return;
}
}
@ -612,7 +612,7 @@ void GcodeSuite::G26() {
g26_nozzle = parser.value_float();
if (!WITHIN(g26_nozzle, 0.1, 1.0)) {
SERIAL_PROTOCOLLNPGM("?Specified nozzle size not plausible.");
return G26_ERR;
return;
}
}
@ -622,7 +622,7 @@ void GcodeSuite::G26() {
g26_prime_flag = -1;
#else
SERIAL_PROTOCOLLNPGM("?Prime length must be specified when not using an LCD.");
return G26_ERR;
return;
#endif
}
else {
@ -630,7 +630,7 @@ void GcodeSuite::G26() {
g26_prime_length = parser.value_linear_units();
if (!WITHIN(g26_prime_length, 0.0, 25.0)) {
SERIAL_PROTOCOLLNPGM("?Specified prime length not plausible.");
return G26_ERR;
return;
}
}
}
@ -639,7 +639,7 @@ void GcodeSuite::G26() {
g26_filament_diameter = parser.value_linear_units();
if (!WITHIN(g26_filament_diameter, 1.0, 4.0)) {
SERIAL_PROTOCOLLNPGM("?Specified filament size not plausible.");
return G26_ERR;
return;
}
}
g26_extrusion_multiplier *= sq(1.75) / sq(g26_filament_diameter); // If we aren't using 1.75mm filament, we need to
@ -652,7 +652,7 @@ void GcodeSuite::G26() {
g26_hotend_temp = parser.value_celsius();
if (!WITHIN(g26_hotend_temp, 165, 280)) {
SERIAL_PROTOCOLLNPGM("?Specified nozzle temperature not plausible.");
return G26_ERR;
return;
}
}
@ -668,14 +668,14 @@ void GcodeSuite::G26() {
#else
if (!parser.seen('R')) {
SERIAL_PROTOCOLLNPGM("?(R)epeat must be specified when not using an LCD.");
return G26_ERR;
return;
}
else
g26_repeats = parser.has_value() ? parser.value_int() : GRID_MAX_POINTS + 1;
#endif
if (g26_repeats < 1) {
SERIAL_PROTOCOLLNPGM("?(R)epeat value not plausible; must be at least 1.");
return G26_ERR;
return;
}
g26_x_pos = parser.seenval('X') ? RAW_X_POSITION(parser.value_linear_units()) : current_position[X_AXIS],
@ -683,7 +683,7 @@ void GcodeSuite::G26() {
if (!position_is_reachable(g26_x_pos, g26_y_pos)) {
SERIAL_PROTOCOLLNPGM("?Specified X,Y coordinate out of bounds.");
return G26_ERR;
return;
}
/**