From 54ec6a0ce2dd5f0a3eecf9d76040fc33cfb95b5d Mon Sep 17 00:00:00 2001 From: Scott Lahteine Date: Thu, 29 Oct 2020 01:14:02 -0500 Subject: [PATCH] Tweak code formatting --- Marlin/src/module/temperature.cpp | 6 +++--- 1 file changed, 3 insertions(+), 3 deletions(-) diff --git a/Marlin/src/module/temperature.cpp b/Marlin/src/module/temperature.cpp index 3468a4c1c..d119a72a6 100644 --- a/Marlin/src/module/temperature.cpp +++ b/Marlin/src/module/temperature.cpp @@ -1233,9 +1233,9 @@ void Temperature::manage_heater() { #ifndef MIN_COOLING_SLOPE_DEG_CHAMBER_VENT #define MIN_COOLING_SLOPE_DEG_CHAMBER_VENT 1.5 #endif - if( (temp_chamber.celsius - temp_chamber.target >= HIGH_EXCESS_HEAT_LIMIT) && !flag_chamber_excess_heat) { - // open vent after MIN_COOLING_SLOPE_TIME_CHAMBER_VENT seconds - // if the temperature did not drop at least MIN_COOLING_SLOPE_DEG_CHAMBER_VENT + if (!flag_chamber_excess_heat && temp_chamber.celsius - temp_chamber.target >= HIGH_EXCESS_HEAT_LIMIT) { + // Open vent after MIN_COOLING_SLOPE_TIME_CHAMBER_VENT seconds if the + // temperature didn't drop at least MIN_COOLING_SLOPE_DEG_CHAMBER_VENT if (next_cool_check_ms_2 == 0 || ELAPSED(ms, next_cool_check_ms_2)) { if (old_temp - temp_chamber.celsius < float(MIN_COOLING_SLOPE_DEG_CHAMBER_VENT)) flag_chamber_excess_heat = true; //the bed is heating the chamber too much next_cool_check_ms_2 = ms + 1000UL * MIN_COOLING_SLOPE_TIME_CHAMBER_VENT;