cooldown blocking selectable by #define.
This commit is contained in:
parent
191f36b493
commit
74d0032e25
@ -84,6 +84,11 @@
|
||||
//#define BED_MAXTEMP 150
|
||||
|
||||
|
||||
// Wait for Cooldown
|
||||
// This defines if the M109 call should not block if it is cooling down.
|
||||
// example: From a current temp of 220, you set M109 S200.
|
||||
// if CooldownNoWait is defined M109 will not wait for the cooldown to finish
|
||||
#define CooldownNoWait true
|
||||
|
||||
// PID settings:
|
||||
// Uncomment the following line to enable PID support.
|
||||
|
@ -517,7 +517,10 @@ inline void process_commands()
|
||||
codenum = 0;
|
||||
if(code_seen('P')) codenum = code_value(); // milliseconds to wait
|
||||
if(code_seen('S')) codenum = code_value() * 1000; // seconds to wait
|
||||
|
||||
st_synchronize();
|
||||
codenum += millis(); // keep track of when we started waiting
|
||||
|
||||
while(millis() < codenum ){
|
||||
manage_heater();
|
||||
}
|
||||
@ -740,7 +743,7 @@ inline void process_commands()
|
||||
while((target_direction ? (isHeatingHotend0()) : (isCoolingHotend0())) ||
|
||||
(residencyStart > -1 && (millis() - residencyStart) < TEMP_RESIDENCY_TIME*1000) ) {
|
||||
#else
|
||||
while ( target_direction ? (isHeatingHotend0()) : (isCoolingHotend0()) ) {
|
||||
while ( target_direction ? (isHeatingHotend0()) : (isCoolingHotend0()&&(CooldownNoWait==false)) ) {
|
||||
#endif //TEMP_RESIDENCY_TIME
|
||||
if( (millis() - codenum) > 1000 )
|
||||
{ //Print Temp Reading every 1 second while heating up/cooling down
|
||||
|
Loading…