Added sanity check for MESH_NUM_X_POINTS and MESH_NUM_Y_POINTS
This commit is contained in:
parent
98f3130a5c
commit
7dc64efe67
@ -420,7 +420,7 @@ const bool Z_PROBE_ENDSTOP_INVERTING = false; // set to true to invert the logic
|
||||
//#define ENDSTOPPULLUP_FIL_RUNOUT // Uncomment to use internal pullup for filament runout pins if the sensor is defined.
|
||||
|
||||
//===========================================================================
|
||||
//============================ Manual Bed Leveling ==========================
|
||||
//============================ Mesh Bed Leveling ============================
|
||||
//===========================================================================
|
||||
|
||||
// #define MANUAL_BED_LEVELING // Add display menu option for bed leveling
|
||||
|
@ -101,6 +101,9 @@
|
||||
#ifdef ENABLE_AUTO_BED_LEVELING
|
||||
#error Select ENABLE_AUTO_BED_LEVELING or MESH_BED_LEVELING, not both
|
||||
#endif
|
||||
#if MESH_NUM_X_POINTS > 7 || MESH_NUM_Y_POINTS > 7
|
||||
#error MESH_NUM_X_POINTS and MESH_NUM_Y_POINTS need to be less than 8
|
||||
#endif
|
||||