Fix G29 E and M48 n

- Users prefer `G29 E` to work like `M48 E` so fixed that
- `M48 n` replaced with `M48 P` (or `p`). `n` legacy support
- Shorten some strings to save precious bytes
- Smaller code for 3-point probing
This commit is contained in:
Scott Lahteine 2015-03-29 18:56:09 -07:00
parent e8ae51bfe3
commit 803425e12c

View File

@ -2108,8 +2108,8 @@ inline void gcode_G28() {
*
* Global Parameters:
*
* E/e By default G29 engages / disengages the probe for each point.
* Include "E" to engage and disengage the probe just once.
* E/e By default G29 will engages the probe, test the bed, then disengage.
* Include "E" to engage/disengage the probe for each sample.
* There's no extra effect if you have a fixed probe.
* Usage: "G29 E" or "G29 e"
*
@ -2135,7 +2135,7 @@ inline void gcode_G28() {
}
bool dryrun = code_seen('D') || code_seen('d');
bool enhanced_g29 = code_seen('E') || code_seen('e');
bool engage_probe_for_each_reading = code_seen('E') || code_seen('e');
#ifdef AUTO_BED_LEVELING_GRID
@ -2293,16 +2293,14 @@ inline void gcode_G28() {
// Enhanced G29 - Do not retract servo between probes
ProbeAction act;
if (enhanced_g29) {
if (yProbe == front_probe_bed_position && xCount == 0)
if (engage_probe_for_each_reading)
act = ProbeEngageAndRetract;
else if (yProbe == front_probe_bed_position && xCount == 0)
act = ProbeEngage;
else if (yProbe == front_probe_bed_position + (yGridSpacing * (auto_bed_leveling_grid_points - 1)) && xCount == auto_bed_leveling_grid_points - 1)
act = ProbeRetract;
else
act = ProbeStay;
}
else
act = ProbeEngageAndRetract;
measured_z = probe_pt(xProbe, yProbe, z_before, act, verbose_level);
@ -2386,18 +2384,14 @@ inline void gcode_G28() {
// Probe at 3 arbitrary points
float z_at_pt_1, z_at_pt_2, z_at_pt_3;
if (enhanced_g29) {
// Basic Enhanced G29
z_at_pt_1 = probe_pt(ABL_PROBE_PT_1_X, ABL_PROBE_PT_1_Y, Z_RAISE_BEFORE_PROBING, ProbeEngage, verbose_level);
z_at_pt_2 = probe_pt(ABL_PROBE_PT_2_X, ABL_PROBE_PT_2_Y, current_position[Z_AXIS] + Z_RAISE_BETWEEN_PROBINGS, ProbeStay, verbose_level);
z_at_pt_3 = probe_pt(ABL_PROBE_PT_3_X, ABL_PROBE_PT_3_Y, current_position[Z_AXIS] + Z_RAISE_BETWEEN_PROBINGS, ProbeRetract, verbose_level);
}
else {
z_at_pt_1 = probe_pt(ABL_PROBE_PT_1_X, ABL_PROBE_PT_1_Y, Z_RAISE_BEFORE_PROBING, ProbeEngageAndRetract, verbose_level);
z_at_pt_2 = probe_pt(ABL_PROBE_PT_2_X, ABL_PROBE_PT_2_Y, current_position[Z_AXIS] + Z_RAISE_BETWEEN_PROBINGS, ProbeEngageAndRetract, verbose_level);
z_at_pt_3 = probe_pt(ABL_PROBE_PT_3_X, ABL_PROBE_PT_3_Y, current_position[Z_AXIS] + Z_RAISE_BETWEEN_PROBINGS, ProbeEngageAndRetract, verbose_level);
}
ProbeAction p1, p2, p3;
if (engage_probe_for_each_reading)
p1 = p2 = p3 = ProbeEngageAndRetract;
else
p1 = ProbeEngage, p2 = ProbeStay, p3 = ProbeRetract;
z_at_pt_1 = probe_pt(ABL_PROBE_PT_1_X, ABL_PROBE_PT_1_Y, Z_RAISE_BEFORE_PROBING, p1, verbose_level);
z_at_pt_2 = probe_pt(ABL_PROBE_PT_2_X, ABL_PROBE_PT_2_Y, current_position[Z_AXIS] + Z_RAISE_BETWEEN_PROBINGS, p2, verbose_level);
z_at_pt_3 = probe_pt(ABL_PROBE_PT_3_X, ABL_PROBE_PT_3_Y, current_position[Z_AXIS] + Z_RAISE_BETWEEN_PROBINGS, p3, verbose_level);
clean_up_after_endstop_move();
if (!dryrun) set_bed_level_equation_3pts(z_at_pt_1, z_at_pt_2, z_at_pt_3);
@ -2764,7 +2758,7 @@ inline void gcode_M42() {
*
* Usage:
* M48 <n#> <X#> <Y#> <V#> <E> <L#>
* n = Number of samples (4-50, default 10)
* P = Number of sampled points (4-50, default 10)
* X = Sample X position
* Y = Sample Y position
* V = Verbose level (0-4, default=1)
@ -2798,10 +2792,10 @@ inline void gcode_M42() {
if (verbose_level > 0)
SERIAL_PROTOCOLPGM("M48 Z-Probe Repeatability test\n");
if (code_seen('n')) {
if (code_seen('P') || code_seen('p') || code_seen('n')) { // `n` for legacy support only - please use `P`!
n_samples = code_value();
if (n_samples < 4 || n_samples > 50) {
SERIAL_PROTOCOLPGM("?Specified sample size not plausible (4-50).\n");
SERIAL_PROTOCOLPGM("?Sample size not plausible (4-50).\n");
return;
}
}
@ -2818,7 +2812,7 @@ inline void gcode_M42() {
if (code_seen('X') || code_seen('x')) {
X_probe_location = code_value() - X_PROBE_OFFSET_FROM_EXTRUDER;
if (X_probe_location < X_MIN_POS || X_probe_location > X_MAX_POS) {
SERIAL_PROTOCOLPGM("?Specified X position out of range.\n");
SERIAL_PROTOCOLPGM("?X position out of range.\n");
return;
}
}
@ -2826,7 +2820,7 @@ inline void gcode_M42() {
if (code_seen('Y') || code_seen('y')) {
Y_probe_location = code_value() - Y_PROBE_OFFSET_FROM_EXTRUDER;
if (Y_probe_location < Y_MIN_POS || Y_probe_location > Y_MAX_POS) {
SERIAL_PROTOCOLPGM("?Specified Y position out of range.\n");
SERIAL_PROTOCOLPGM("?Y position out of range.\n");
return;
}
}
@ -2835,7 +2829,7 @@ inline void gcode_M42() {
n_legs = code_value();
if (n_legs == 1) n_legs = 2;
if (n_legs < 0 || n_legs > 15) {
SERIAL_PROTOCOLPGM("?Specified number of legs in movement not plausible (0-15).\n");
SERIAL_PROTOCOLPGM("?Number of legs in movement not plausible (0-15).\n");
return;
}
}
@ -2858,7 +2852,7 @@ inline void gcode_M42() {
// use that as a starting point for each probe.
//
if (verbose_level > 2)
SERIAL_PROTOCOL("Positioning probe for the test.\n");
SERIAL_PROTOCOL("Positioning the probe...\n");
plan_buffer_line( X_probe_location, Y_probe_location, Z_start_location,
ext_position,
@ -2907,7 +2901,7 @@ inline void gcode_M42() {
//SERIAL_ECHOPAIR("starting radius: ",radius);
//SERIAL_ECHOPAIR(" theta: ",theta);
//SERIAL_ECHOPAIR(" direction: ",rotational_direction);
//SERIAL_PROTOCOLLNPGM("");
//SERIAL_EOL;
float dir = rotational_direction ? 1 : -1;
for (l = 0; l < n_legs - 1; l++) {
@ -2926,7 +2920,7 @@ inline void gcode_M42() {
if (verbose_level > 3) {
SERIAL_ECHOPAIR("x: ", X_current);
SERIAL_ECHOPAIR("y: ", Y_current);
SERIAL_PROTOCOLLNPGM("");
SERIAL_EOL;
}
do_blocking_move_to( X_current, Y_current, Z_current );