Move and update heated chamber settings (#13671)
Co-Authored-By: the-real-orca <stephan.veigl@gmail.com>
This commit is contained in:
parent
62b4265410
commit
84273557f9
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 0
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -918,7 +918,7 @@
|
||||
#define HAS_TEMP_HOTEND (HAS_TEMP_ADC_0 || ENABLED(HEATER_0_USES_MAX6675))
|
||||
#define HAS_TEMP_BED HAS_TEMP_ADC_BED
|
||||
#define HAS_TEMP_CHAMBER HAS_TEMP_ADC_CHAMBER
|
||||
#define HAS_HEATED_CHAMBER (HAS_TEMP_CHAMBER && PIN_EXISTS(CHAMBER_HEATER))
|
||||
#define HAS_HEATED_CHAMBER (HAS_TEMP_CHAMBER && PIN_EXISTS(HEATER_CHAMBER))
|
||||
|
||||
// Heaters
|
||||
#define HAS_HEATER_0 (PIN_EXISTS(HEATER_0))
|
||||
|
@ -343,6 +343,8 @@
|
||||
#error "MAX6675_SS2 is now MAX6675_SS2_PIN. Please update your configuration and/or pins."
|
||||
#elif defined(SPINDLE_LASER_ENABLE_PIN)
|
||||
#error "SPINDLE_LASER_ENABLE_PIN is now SPINDLE_LASER_ENA_PIN. Please update your configuration and/or pins."
|
||||
#elif defined(CHAMBER_HEATER_PIN)
|
||||
#error "CHAMBER_HEATER_PIN is now HEATER_CHAMBER_PIN. Please update your configuration and/or pins."
|
||||
#elif defined(TMC_Z_CALIBRATION)
|
||||
#error "TMC_Z_CALIBRATION has been deprecated in favor of Z_STEPPER_AUTO_ALIGN. Please update your configuration."
|
||||
#elif defined(Z_MIN_PROBE_ENDSTOP)
|
||||
|
@ -595,10 +595,23 @@ temp_range_t Temperature::temp_range[HOTENDS] = ARRAY_BY_HOTENDS(sensor_heater_0
|
||||
|
||||
Temperature::Temperature() { }
|
||||
|
||||
int Temperature::getHeaterPower(const int heater) {
|
||||
int16_t Temperature::getHeaterPower(const int8_t heater) {
|
||||
return (
|
||||
#if HAS_HEATED_CHAMBER
|
||||
#if HAS_HEATED_BED
|
||||
heater < 0 ? temp_bed.soft_pwm_amount :
|
||||
heater == -2
|
||||
#else
|
||||
heater < 0
|
||||
#endif
|
||||
? temp_chamber.soft_pwm_amount :
|
||||
#endif
|
||||
#if HAS_HEATED_BED
|
||||
#if HAS_HEATED_CHAMBER
|
||||
heater == -1
|
||||
#else
|
||||
heater < 0
|
||||
#endif
|
||||
? temp_bed.soft_pwm_amount :
|
||||
#endif
|
||||
temp_hotend[heater].soft_pwm_amount
|
||||
);
|
||||
@ -1073,11 +1086,11 @@ void Temperature::manage_heater() {
|
||||
|
||||
if (WITHIN(temp_chamber.current, CHAMBER_MINTEMP, CHAMBER_MAXTEMP)) {
|
||||
#if ENABLED(CHAMBER_LIMIT_SWITCHING)
|
||||
if (temp_chamber.current >= temp_chamber.target + CHAMBER_HYSTERESIS)
|
||||
if (temp_chamber.current >= temp_chamber.target + TEMP_CHAMBER_HYSTERESIS)
|
||||
temp_chamber.soft_pwm_amount = 0;
|
||||
else if (temp_chamber.current <= temp_chamber.target - (CHAMBER_HYSTERESIS))
|
||||
else if (temp_chamber.current <= temp_chamber.target - (TEMP_CHAMBER_HYSTERESIS))
|
||||
temp_chamber.soft_pwm_amount = MAX_CHAMBER_POWER >> 1;
|
||||
#else // !PIDTEMPCHAMBER && !CHAMBER_LIMIT_SWITCHING
|
||||
#else
|
||||
temp_chamber.soft_pwm_amount = temp_chamber.current < temp_chamber.target ? MAX_CHAMBER_POWER >> 1 : 0;
|
||||
#endif
|
||||
}
|
||||
@ -2017,11 +2030,7 @@ void Temperature::readings_ready() {
|
||||
#else
|
||||
#define CHAMBERCMP(A,B) ((A)>=(B))
|
||||
#endif
|
||||
const bool chamber_on = (temp_chamber.target > 0)
|
||||
#if ENABLED(PIDTEMPCHAMBER)
|
||||
|| (temp_chamber.soft_pwm_amount > 0)
|
||||
#endif
|
||||
;
|
||||
const bool chamber_on = (temp_chamber.target > 0);
|
||||
if (CHAMBERCMP(temp_chamber.raw, maxtemp_raw_CHAMBER)) max_temp_error(-2);
|
||||
if (chamber_on && CHAMBERCMP(mintemp_raw_CHAMBER, temp_chamber.raw)) min_temp_error(-2);
|
||||
#endif
|
||||
@ -2602,11 +2611,12 @@ void Temperature::isr() {
|
||||
, e
|
||||
);
|
||||
#endif
|
||||
SERIAL_ECHOPGM(" @:");
|
||||
SERIAL_ECHO(getHeaterPower(target_extruder));
|
||||
SERIAL_ECHOPAIR(" @:", getHeaterPower(target_extruder));
|
||||
#if HAS_HEATED_BED
|
||||
SERIAL_ECHOPGM(" B@:");
|
||||
SERIAL_ECHO(getHeaterPower(-1));
|
||||
SERIAL_ECHOPAIR(" B@:", getHeaterPower(-1));
|
||||
#endif
|
||||
#if HAS_HEATED_CHAMBER
|
||||
SERIAL_ECHOPAIR(" C@:", getHeaterPower(-2));
|
||||
#endif
|
||||
#if HOTENDS > 1
|
||||
HOTEND_LOOP() {
|
||||
|
@ -206,17 +206,11 @@ struct PIDHeaterInfo : public HeaterInfo {
|
||||
typedef heater_info_t bed_info_t;
|
||||
#endif
|
||||
#endif
|
||||
#if HAS_TEMP_CHAMBER
|
||||
#if HAS_HEATED_CHAMBER
|
||||
#if ENABLED(PIDTEMPCHAMBER)
|
||||
typedef struct PIDHeaterInfo<PID_t> chamber_info_t;
|
||||
#else
|
||||
typedef heater_info_t chamber_info_t;
|
||||
#endif
|
||||
#else
|
||||
#elif HAS_TEMP_CHAMBER
|
||||
typedef temp_info_t chamber_info_t;
|
||||
#endif
|
||||
#endif
|
||||
|
||||
// Heater idle handling
|
||||
typedef struct {
|
||||
@ -339,9 +333,7 @@ class Temperature {
|
||||
#if WATCH_CHAMBER
|
||||
static heater_watch_t watch_chamber;
|
||||
#endif
|
||||
#if DISABLED(PIDTEMPCHAMBER)
|
||||
static millis_t next_chamber_check_ms;
|
||||
#endif
|
||||
#ifdef CHAMBER_MINTEMP
|
||||
static int16_t mintemp_raw_CHAMBER;
|
||||
#endif
|
||||
@ -653,7 +645,7 @@ class Temperature {
|
||||
/**
|
||||
* The software PWM power for a heater
|
||||
*/
|
||||
static int getHeaterPower(const int heater);
|
||||
static int16_t getHeaterPower(const int8_t heater);
|
||||
|
||||
/**
|
||||
* Switch off all heaters, set all target temperatures to 0
|
||||
|
@ -42,7 +42,7 @@ opt_enable PIDTEMPBED FIX_MOUNTED_PROBE Z_SAFE_HOMING EEPROM_SETTINGS \
|
||||
MAX7219_DEBUG LED_CONTROL_MENU CASE_LIGHT_ENABLE CASE_LIGHT_USE_NEOPIXEL CODEPENDENT_XY_HOMING BACKLASH_COMPENSATION BACKLASH_GCODE
|
||||
opt_enable SLOW_PWM_HEATERS THERMAL_PROTECTION_CHAMBER
|
||||
opt_set TEMP_SENSOR_CHAMBER 3
|
||||
opt_set CHAMBER_HEATER_PIN 45
|
||||
opt_set HEATER_CHAMBER_PIN 45
|
||||
exec_test $1 $2 "RAMPS with 2 extruders, RRDFGSC, Linear ABL, LEDs, and many options"
|
||||
|
||||
#
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 0
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -481,7 +476,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 7
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 250
|
||||
#define HEATER_5_MAXTEMP 250
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -485,7 +480,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 20
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 130
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -487,7 +482,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 5
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 5
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 11
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 130
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -487,7 +482,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -392,7 +392,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 5
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -411,8 +410,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -422,7 +419,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -434,7 +430,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 130
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -483,7 +478,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -481,7 +476,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 13
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -54,6 +54,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -131,8 +144,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 5
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 115
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 60
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 115
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 0
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 260
|
||||
#define HEATER_5_MAXTEMP 260
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -464,7 +459,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -399,7 +399,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 0
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -418,8 +417,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -429,7 +426,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -441,7 +437,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 100
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -477,7 +472,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 0
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 260
|
||||
#define HEATER_5_MAXTEMP 260
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -464,7 +459,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -392,7 +392,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -411,8 +410,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -422,7 +419,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -434,7 +430,6 @@
|
||||
#define HEATER_4_MAXTEMP 415
|
||||
#define HEATER_5_MAXTEMP 415
|
||||
#define BED_MAXTEMP 165
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -477,7 +472,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 5
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 120
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -481,7 +476,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 5
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 120
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 5
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 120
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -400,7 +400,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 5
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -419,8 +418,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -430,7 +427,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -442,7 +438,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 120
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -490,7 +485,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -481,7 +476,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 75
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -480,7 +475,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 125
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -480,7 +475,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -481,7 +476,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -393,7 +393,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 0
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -412,8 +411,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -423,7 +420,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -435,7 +431,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -484,7 +479,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -464,7 +459,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -464,7 +459,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -466,7 +461,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 245
|
||||
#define HEATER_5_MAXTEMP 245
|
||||
#define BED_MAXTEMP 115
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -481,7 +476,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -436,7 +436,6 @@
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#endif
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -455,8 +454,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -465,7 +462,6 @@
|
||||
#define HEATER_3_MINTEMP 5
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -480,7 +476,6 @@
|
||||
#else
|
||||
#define BED_MAXTEMP 100
|
||||
#endif
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -528,7 +523,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -406,7 +406,6 @@
|
||||
#endif
|
||||
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -425,8 +424,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -436,7 +433,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -448,7 +444,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -498,7 +493,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -400,7 +400,6 @@
|
||||
#endif
|
||||
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -419,8 +418,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -430,7 +427,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -442,7 +438,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -485,7 +480,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -466,7 +461,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -466,7 +461,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -486,7 +481,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -480,7 +475,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 125
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -486,7 +481,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 125
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -486,7 +481,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 125
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -480,7 +475,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -396,7 +396,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1 // measured to be satisfactorily accurate on center of bed within +/- 1 degC.
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -415,8 +414,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -426,7 +423,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -438,7 +434,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 120
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -486,7 +481,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -411,7 +411,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -430,8 +429,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -441,7 +438,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -453,7 +449,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -496,7 +491,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -399,7 +399,6 @@
|
||||
// The reasons are inconclusive so I leave at 1
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -418,8 +417,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -429,7 +426,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -441,7 +437,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -484,7 +479,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 11
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 100
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -475,7 +470,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 0
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -391,7 +391,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 0
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -410,8 +409,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -421,7 +418,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -433,7 +429,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -476,7 +471,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
@ -50,6 +50,19 @@
|
||||
#define HEATER_BED_INVERTING true
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Heated Chamber settings
|
||||
*/
|
||||
#if TEMP_SENSOR_CHAMBER
|
||||
#define CHAMBER_MINTEMP 5
|
||||
#define CHAMBER_MAXTEMP 60
|
||||
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
|
||||
#define THERMAL_PROTECTION_CHAMBER // Enable thermal protection for the heated chamber
|
||||
//#define CHAMBER_LIMIT_SWITCHING
|
||||
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
|
||||
//#define HEATER_CHAMBER_INVERTING false
|
||||
#endif
|
||||
|
||||
#if DISABLED(PIDTEMPBED)
|
||||
#define BED_CHECK_INTERVAL 5000 // ms between checks in bang-bang control
|
||||
#if ENABLED(BED_LIMIT_SWITCHING)
|
||||
@ -127,8 +140,8 @@
|
||||
#endif
|
||||
|
||||
#if ENABLED(PIDTEMP)
|
||||
// this adds an experimental additional term to the heating power, proportional to the extrusion speed.
|
||||
// if Kc is chosen well, the additional required power due to increased melting should be compensated.
|
||||
// Add an experimental additional term to the heater power, proportional to the extrusion speed.
|
||||
// A well-chosen Kc value should add just enough power to melt the increased material volume.
|
||||
//#define PID_EXTRUSION_SCALING
|
||||
#if ENABLED(PID_EXTRUSION_SCALING)
|
||||
#define DEFAULT_Kc (100) //heating power=Kc*(e_speed)
|
||||
|
@ -392,7 +392,6 @@
|
||||
#define TEMP_SENSOR_5 0
|
||||
#define TEMP_SENSOR_BED 1
|
||||
#define TEMP_SENSOR_CHAMBER 0
|
||||
#define CHAMBER_HEATER_PIN -1 // On/off pin for enclosure heating system
|
||||
|
||||
// Dummy thermistor constant temperature readings, for use with 998 and 999
|
||||
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||
@ -411,8 +410,6 @@
|
||||
#define TEMP_BED_WINDOW 1 // (°C) Temperature proximity for the "temperature reached" timer
|
||||
#define TEMP_BED_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
#define TEMP_CHAMBER_HYSTERESIS 3 // (°C) Temperature proximity considered "close enough" to the target
|
||||
|
||||
// Below this temperature the heater will be switched off
|
||||
// because it probably indicates a broken thermistor wire.
|
||||
#define HEATER_0_MINTEMP 5
|
||||
@ -422,7 +419,6 @@
|
||||
#define HEATER_4_MINTEMP 5
|
||||
#define HEATER_5_MINTEMP 5
|
||||
#define BED_MINTEMP 5
|
||||
#define CHAMBER_MINTEMP 5
|
||||
|
||||
// Above this temperature the heater will be switched off.
|
||||
// This can protect components from overheating, but NOT from shorts and failures.
|
||||
@ -434,7 +430,6 @@
|
||||
#define HEATER_4_MAXTEMP 275
|
||||
#define HEATER_5_MAXTEMP 275
|
||||
#define BED_MAXTEMP 150
|
||||
#define CHAMBER_MAXTEMP 100
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID Settings ================================
|
||||
@ -477,7 +472,7 @@
|
||||
#endif // PIDTEMP
|
||||
|
||||
//===========================================================================
|
||||
//============================= PID > Bed Temperature Control ===============
|
||||
//====================== PID > Bed Temperature Control ======================
|
||||
//===========================================================================
|
||||
|
||||
/**
|
||||
|
Some files were not shown because too many files have changed in this diff Show More