Dummy Thermistor Table for testing purposes

Am I the only one who always need to change the thermistortable.h to add
a dummy table??
Ok, it is done. Just set the thermistor to 999 and it will always read
25C. Great for Testing or Development purposes.
This commit is contained in:
alexborro 2015-02-22 11:02:04 -03:00
parent c3c50528e6
commit a57869ba49
2 changed files with 11 additions and 0 deletions

View File

@ -118,6 +118,7 @@ Here are some standard links for getting your machine calibrated:
// 1010 is Pt1000 with 1k pullup (non standard) // 1010 is Pt1000 with 1k pullup (non standard)
// 147 is Pt100 with 4k7 pullup // 147 is Pt100 with 4k7 pullup
// 110 is Pt100 with 1k pullup (non standard) // 110 is Pt100 with 1k pullup (non standard)
// 999 is a Dummy Table. It will ALWAYS read 25C.. Use it for Testing or Development purposes. NEVER for production machine.
#define TEMP_SENSOR_0 -1 #define TEMP_SENSOR_0 -1
#define TEMP_SENSOR_1 -1 #define TEMP_SENSOR_1 -1

View File

@ -1095,6 +1095,16 @@ const short temptable_1047[][2] PROGMEM = {
}; };
#endif #endif
#if (THERMISTORHEATER_0 == 999) || (THERMISTORHEATER_1 == 999) || (THERMISTORHEATER_2 == 999) || (THERMISTORHEATER_3 == 999) || (THERMISTORBED == 999) //User defined table
// Dummy Thermistor table.. It will ALWAYS read 25C.
const short temptable_999[][2] PROGMEM = {
{1*OVERSAMPLENR, 25},
{1023*OVERSAMPLENR, 25}
};
#endif
#define _TT_NAME(_N) temptable_ ## _N #define _TT_NAME(_N) temptable_ ## _N
#define TT_NAME(_N) _TT_NAME(_N) #define TT_NAME(_N) _TT_NAME(_N)