Extend the idea of dummy temperature sensors.
Added a second sensor and made them configurable.
This commit is contained in:
parent
e6af82ba2f
commit
c6d2ebe452
@ -118,7 +118,10 @@ Here are some standard links for getting your machine calibrated:
|
|||||||
// 1010 is Pt1000 with 1k pullup (non standard)
|
// 1010 is Pt1000 with 1k pullup (non standard)
|
||||||
// 147 is Pt100 with 4k7 pullup
|
// 147 is Pt100 with 4k7 pullup
|
||||||
// 110 is Pt100 with 1k pullup (non standard)
|
// 110 is Pt100 with 1k pullup (non standard)
|
||||||
// 999 is a Dummy Table. It will ALWAYS read 25C.. Use it for Testing or Development purposes. NEVER for production machine.
|
// 998 and 999 are Dummy Tables. They will ALWAYS read 25°C or the temperature defined below.
|
||||||
|
// Use it for Testing or Development purposes. NEVER for production machine.
|
||||||
|
// #define DUMMY_THERMISTOR_998_VALUE 25
|
||||||
|
// #define DUMMY_THERMISTOR_999_VALUE 100
|
||||||
|
|
||||||
#define TEMP_SENSOR_0 -1
|
#define TEMP_SENSOR_0 -1
|
||||||
#define TEMP_SENSOR_1 -1
|
#define TEMP_SENSOR_1 -1
|
||||||
|
@ -1096,13 +1096,26 @@ const short temptable_1047[][2] PROGMEM = {
|
|||||||
#endif
|
#endif
|
||||||
|
|
||||||
#if (THERMISTORHEATER_0 == 999) || (THERMISTORHEATER_1 == 999) || (THERMISTORHEATER_2 == 999) || (THERMISTORHEATER_3 == 999) || (THERMISTORBED == 999) //User defined table
|
#if (THERMISTORHEATER_0 == 999) || (THERMISTORHEATER_1 == 999) || (THERMISTORHEATER_2 == 999) || (THERMISTORHEATER_3 == 999) || (THERMISTORBED == 999) //User defined table
|
||||||
// Dummy Thermistor table.. It will ALWAYS read 25C.
|
// Dummy Thermistor table.. It will ALWAYS read a fixed value.
|
||||||
const short temptable_999[][2] PROGMEM = {
|
#ifndef DUMMY_THERMISTOR_999_VALUE
|
||||||
{1*OVERSAMPLENR, 25},
|
#define DUMMY_THERMISTOR_999_VALUE 25
|
||||||
{1023*OVERSAMPLENR, 25}
|
#endif
|
||||||
|
const short temptable_999[][2] PROGMEM = {
|
||||||
|
{1*OVERSAMPLENR, DUMMY_THERMISTOR_999_VALUE},
|
||||||
|
{1023*OVERSAMPLENR, DUMMY_THERMISTOR_999_VALUE}
|
||||||
};
|
};
|
||||||
#endif
|
#endif
|
||||||
|
|
||||||
|
#if (THERMISTORHEATER_0 == 998) || (THERMISTORHEATER_1 == 998) || (THERMISTORHEATER_2 == 998) || (THERMISTORHEATER_3 == 998) || (THERMISTORBED == 998) //User defined table
|
||||||
|
// Dummy Thermistor table.. It will ALWAYS read a fixed value.
|
||||||
|
#ifndef DUMMY_THERMISTOR_998_VALUE
|
||||||
|
#define DUMMY_THERMISTOR_998_VALUE 25
|
||||||
|
#endif
|
||||||
|
const short temptable_998[][2] PROGMEM = {
|
||||||
|
{1*OVERSAMPLENR, DUMMY_THERMISTOR_998_VALUE},
|
||||||
|
{1023*OVERSAMPLENR, DUMMY_THERMISTOR_998_VALUE}
|
||||||
|
};
|
||||||
|
#endif
|
||||||
|
|
||||||
|
|
||||||
#define _TT_NAME(_N) temptable_ ## _N
|
#define _TT_NAME(_N) temptable_ ## _N
|
||||||
|