Cleanup of spacing and formatting
This commit is contained in:
parent
9f295581f0
commit
e4937b0285
@ -1551,7 +1551,7 @@ inline void set_destination_to_current() { COPY(destination, current_position);
|
||||
|
||||
planner.buffer_line_kinematic(destination, MMS_SCALED(fr_mm_s ? fr_mm_s : feedrate_mm_s), active_extruder);
|
||||
#endif
|
||||
|
||||
|
||||
set_current_to_destination();
|
||||
}
|
||||
#endif // IS_KINEMATIC
|
||||
@ -2362,7 +2362,7 @@ static void clean_up_after_endstop_or_probe_move() {
|
||||
else { // leveling from off to on
|
||||
ubl.state.active = true; // enable BEFORE calling unapply_leveling, otherwise ignored
|
||||
// change physical current_position to unleveled current_position without moving steppers.
|
||||
planner.unapply_leveling(current_position);
|
||||
planner.unapply_leveling(current_position);
|
||||
}
|
||||
#else
|
||||
ubl.state.active = enable; // just flip the bit, current_position will be wrong until next move.
|
||||
@ -2376,8 +2376,12 @@ static void clean_up_after_endstop_or_probe_move() {
|
||||
(void)bilinear_z_offset(reset);
|
||||
#endif
|
||||
|
||||
// Enable or disable leveling compensation in the planner
|
||||
planner.abl_enabled = enable;
|
||||
|
||||
if (!enable)
|
||||
// When disabling just get the current position from the steppers.
|
||||
// This will yield the smallest error when first converted back to steps.
|
||||
set_current_from_steppers_for_axis(
|
||||
#if ABL_PLANAR
|
||||
ALL_AXES
|
||||
@ -2386,9 +2390,11 @@ static void clean_up_after_endstop_or_probe_move() {
|
||||
#endif
|
||||
);
|
||||
else
|
||||
// When enabling, remove compensation from the current position,
|
||||
// so compensation will give the right stepper counts.
|
||||
planner.unapply_leveling(current_position);
|
||||
|
||||
#endif
|
||||
#endif // ABL
|
||||
}
|
||||
}
|
||||
|
||||
@ -2396,24 +2402,23 @@ static void clean_up_after_endstop_or_probe_move() {
|
||||
|
||||
void set_z_fade_height(const float zfh) {
|
||||
|
||||
const bool level_active = leveling_is_active();
|
||||
|
||||
#if ENABLED(AUTO_BED_LEVELING_UBL)
|
||||
|
||||
const bool level_active = leveling_is_active();
|
||||
if (level_active) {
|
||||
if (level_active)
|
||||
set_bed_leveling_enabled(false); // turn off before changing fade height for proper apply/unapply leveling to maintain current_position
|
||||
}
|
||||
planner.z_fade_height = zfh;
|
||||
planner.inverse_z_fade_height = RECIPROCAL(zfh);
|
||||
if (level_active) {
|
||||
if (level_active)
|
||||
set_bed_leveling_enabled(true); // turn back on after changing fade height
|
||||
}
|
||||
|
||||
#else
|
||||
|
||||
planner.z_fade_height = zfh;
|
||||
planner.inverse_z_fade_height = RECIPROCAL(zfh);
|
||||
|
||||
if (leveling_is_active()) {
|
||||
if (level_active) {
|
||||
set_current_from_steppers_for_axis(
|
||||
#if ABL_PLANAR
|
||||
ALL_AXES
|
||||
@ -9643,7 +9648,7 @@ inline void gcode_M355() {
|
||||
#if HAS_CASE_LIGHT
|
||||
uint8_t args = 0;
|
||||
if (parser.seen('P')) ++args, case_light_brightness = parser.value_byte();
|
||||
if (parser.seen('S')) ++args, case_light_on = parser.value_bool();
|
||||
if (parser.seen('S')) ++args, case_light_on = parser.value_bool();
|
||||
if (args) update_case_light();
|
||||
|
||||
// always report case light status
|
||||
|
@ -788,7 +788,7 @@
|
||||
#define PAUSE_PARK_Z_FEEDRATE 5 // Z axis feedrate in mm/s (not used for delta printers)
|
||||
#define PAUSE_PARK_RETRACT_FEEDRATE 60 // Initial retract feedrate in mm/s
|
||||
#define PAUSE_PARK_RETRACT_LENGTH 2 // Initial retract in mm
|
||||
|
||||
|
||||
// It is a short retract used immediately after print interrupt before move to filament exchange position
|
||||
#define FILAMENT_CHANGE_UNLOAD_FEEDRATE 10 // Unload filament feedrate in mm/s - filament unloading can be fast
|
||||
#define FILAMENT_CHANGE_UNLOAD_LENGTH 100 // Unload filament length from hotend in mm
|
||||
|
@ -318,7 +318,7 @@
|
||||
#define K1 0.95 //smoothing factor within the PID
|
||||
|
||||
// If you are using a pre-configured hotend then you can use one of the value sets by uncommenting it
|
||||
|
||||
|
||||
// Malyan M150 example
|
||||
#define DEFAULT_Kp 29
|
||||
#define DEFAULT_Ki 2
|
||||
|
@ -1,3 +1,3 @@
|
||||
# Configuration for Malyan M150 hobbyking printer
|
||||
# config without automatic bed level sensor
|
||||
# or in other words, "as stock"
|
||||
# config without automatic bed level sensor
|
||||
# or in other words, "as stock"
|
||||
|
@ -788,7 +788,7 @@
|
||||
#define PAUSE_PARK_Z_FEEDRATE 5 // Z axis feedrate in mm/s (not used for delta printers)
|
||||
#define PAUSE_PARK_RETRACT_FEEDRATE 60 // Initial retract feedrate in mm/s
|
||||
#define PAUSE_PARK_RETRACT_LENGTH 2 // Initial retract in mm
|
||||
|
||||
|
||||
// It is a short retract used immediately after print interrupt before move to filament exchange position
|
||||
#define FILAMENT_CHANGE_UNLOAD_FEEDRATE 10 // Unload filament feedrate in mm/s - filament unloading can be fast
|
||||
#define FILAMENT_CHANGE_UNLOAD_LENGTH 100 // Unload filament length from hotend in mm
|
||||
|
@ -74,7 +74,7 @@
|
||||
//
|
||||
// Misc
|
||||
//
|
||||
#if ENABLED(CASE_LIGHT_ENABLE) && PIN_EXISTS(CASE_LIGHT) && PIN_EXISTS(STAT_LED_RED) && STAT_LED_RED_PIN == CASE_LIGHT_PIN
|
||||
#if ENABLED(CASE_LIGHT_ENABLE) && PIN_EXISTS(CASE_LIGHT) && PIN_EXISTS(STAT_LED_RED) && STAT_LED_RED_PIN == CASE_LIGHT_PIN
|
||||
#undef STAT_LED_RED_PIN
|
||||
#endif
|
||||
|
||||
|
@ -145,7 +145,7 @@
|
||||
//
|
||||
// Misc. Functions
|
||||
//
|
||||
#if ENABLED(CASE_LIGHT_ENABLE) && PIN_EXISTS(CASE_LIGHT) && defined(DOGLCD_A0) && DOGLCD_A0 == CASE_LIGHT_PIN
|
||||
#if ENABLED(CASE_LIGHT_ENABLE) && PIN_EXISTS(CASE_LIGHT) && defined(DOGLCD_A0) && DOGLCD_A0 == CASE_LIGHT_PIN
|
||||
#undef DOGLCD_A0 // steal pin 44 for the case light; if you have a Viki2 and have connected it
|
||||
#define DOGLCD_A0 57 // following the Panucatt wiring diagram, you may need to tweak these pin assignments
|
||||
// as the wiring diagram uses pin 44 for DOGLCD_A0
|
||||
|
@ -586,7 +586,7 @@ void Stepper::isr() {
|
||||
/**
|
||||
* If a minimum pulse time was specified get the timer 0 value.
|
||||
*
|
||||
* TCNT0 has an 8x prescaler, so it increments every 8 cycles.
|
||||
* TCNT0 has an 8x prescaler, so it increments every 8 cycles.
|
||||
* That's every 0.5µs on 16MHz and every 0.4µs on 20MHz.
|
||||
* 20 counts of TCNT0 -by itself- is a good pulse delay.
|
||||
* 10µs = 160 or 200 cycles.
|
||||
|
Loading…
Reference in New Issue
Block a user